Cold & hot water distribution
Complete internal water networks for every floor and fixture.
- PPR, copper and GI distribution pipework
- Hot water storage and circulation
- Isolation valves, pressure reducing valves and meters
Cold and hot water systems, booster pump sets, storage tanks and underground HDPE water mains — installed, pressure-tested and commissioned on site.
VAKRUM designs and installs water supply systems for hotels, apartments, offices, hospitals, schools and factories across Uganda and East Africa — from the incoming main and storage tanks to the last tap.
We size pipework and pumps from the building’s demand, choose the right pipe material for each service, and pressure-test every system before handover. Underground HDPE mains are joined by butt-fusion or electrofusion by trained operators.
Complete internal water networks for every floor and fixture.
Steady water pressure on every floor, even at peak demand.
Storage sized for daily use and supply interruptions.
Long-life underground pipework with leak-free welded joints.
Lower energy bills for hotels, hospitals and residences.
Finished washrooms supplied and installed to a high standard.




| Material | Typical use | Jointing |
|---|---|---|
| HDPE | Underground water mains and external networks | Butt-fusion or electrofusion |
| PPR | Internal hot and cold water supply | Heat fusion (socket welding) |
| GI / MS steel | Pump rooms, exposed and high-pressure lines | Threaded or grooved |
| Copper | Hot water and specialist areas | Soldered or press-fit |
| Stainless steel | Kitchens, food and pharmaceutical areas | Welded or press-fit |
Our engineers visit site, confirm the scope, measure up and review the architectural or MEP drawings.
System selection, calculations and sizing, then coordinated AutoCAD shop drawings, specifications and a priced BOQ.
Technical submittals for client and consultant approval, then sourcing, import and delivery of the approved brands.
Supervised VAKRUM installation crews working to the approved drawings, with safe-work permits and daily site records.
Hydrostatic pressure tests on every section, flushing and disinfection, pump performance checks and outlet flow checks.
As-built drawings and O&M manuals, then pump servicing, leak repairs, spares and planned maintenance.
Guest rooms, kitchens, laundries and pools
Office blocks, banks and retail centres
Hospitals and clinics
Schools, hostels and universities
Factories, food plants and warehouses
Site water mains and estate networks
Usually because the building relies on mains or tank pressure alone. A correctly sized booster pump set with a pressure vessel gives steady pressure on every floor; we survey the system and size the pumps from the actual demand.
HDPE is our standard choice for underground mains: it does not corrode, it flexes with ground movement and its fused joints are leak-free.
Both. We offer supply-only packages from approved brands, installation-only, or complete supply and installation of washrooms.
Each section is pressure-tested and held before it is concealed or backfilled, then the system is flushed, disinfected and checked for flow and pressure at the outlets.
Send us drawings, a BOQ or a short brief. Our engineers will visit site and return a technical and commercial offer.